CT によるray-summation 画像の画質と臨床的有用性: Digital radiography との比較

Format:
Article
Responsibility:
鈴木, 省吾 ; 市川, 勝弘 ; 玉木, 繁 ; Suzuki, Shogo ; Ichikawa, Katsuhiro ; Tamaki, Shigeru
Language:
Japanese
Published:
日本放射線技術学会 = Japanese Society of Radiological Technology, 2017-01-01
Authors:
鈴木, 省吾
市川, 勝弘
玉木, 繁
Suzuki, Shogo
Ichikawa, Katsuhiro
Tamaki, Shigeru
Read more
Publication info:
日本放射線技術学会雑誌 = Japanese Journal of Radiological Technology
ISSN:
0369-4305  CiNii Research  Webcat Plus  JAIRO
Volume:
73
Number:
5
Start page:
372
End page:
381
Version:
author
Abstract:
Ray-summation (raysum) images reconstructed from computed tomography (CT) volume data resemble digital radiography (DR) images. Therefore, they have a potential to be used instead of DR images.The aim of this study was to compare the physic al image quality evaluated by signal-difference-to-noise ratio (SDNR) and clinical usefulness between raysum and DR images. We employed an oval water phantom simulating adult abdomen for image quality measurement. Raysum images were reconstructed from CT volume data using an assumed x-ray quality of 70 keV. DR images were obtained using an indirect-type flat panel detector system. The normalized noise-power spectrum (NNPS) for various same dose indices (DR: entrance surface dose, CT: CT dose index volume) were measured from raysum and DR images. SDNRs were calculated from the results of NNPSs, modulation transfer function (MTF), and cartilage material contrast. Five experienced observers visually compared each pair of a clinical raysum image and a DR image for nine clinical cases (head, finger, pelvis, and foot). MTF of raysum was significantly lower than that of DR. SDNRs of DR were superior to those of raysum for each dose index, by an average factor of 1.24. For head and pelvis images, raysum images were comparable or a little superior compared with the DR images, because the radiation doses of raysum was much higher than those of DR. For finger and foot cases, the raysum images were inferior to DR images due to its lower resolution. Our results indicated a limited clinical usefulness of raysum compared with DR.<br />出版者照会後に全文公開 Read more
URL:
http://hdl.handle.net/2297/48563
Related Materials

Similar Items:

1
 
2
 
3
 
4
 
5
 
6
 
7
 
8
 
9
 
10
 
11
 
12
 

市川, 勝弘, 原, 孝則, 丹羽, 伸次, 大橋, 一也

日本放射線技術学会 = Japanese Society of Radiological Technology

西丸, 英治, 市川, 勝弘, 藤岡, 知加子, 木口, 雅夫, 石風呂, 実, 鈴木, 正行, Nishimaru, Eiji, &hellip;

医用画象情報学会

田中, 利恵, 市川, 勝弘, 森, 慎一郎, 土橋, 卓, 熊谷, 始紀, 川嶋, 広貴, 箕原, 伸一, 真田, 茂

医用画象情報学会

市川, 勝弘, Ichikawa, Katsuhiro

日本放射線技術学会 = Japanese Society of Radiological Technology

市川, 勝弘

医用画象情報学会

Tanaka, Rie, Ichikawa, Katsuhiro, Matsubara, Kosuke, Kawashima, Hiroki

Japanese Society of Radiological Technology and Japan Society of Medical Physics 日本放射線技術学会 / Springer Verlag (Germany)

Tanaka, Rie, Ichikawa, Katsuhiro, Matsubara, Kosuke, Kawashima, Hiroki

Japan Society of Medical Physics 日本放射線技術学会 / Springer Verlag (Germany)

市川, 勝弘, Ichikawa, Katsuhiro

日本放射線技術学会 = Japanese Society of Radiological Technology

12 eBook CT super basic

市川勝弘

オーム社