※一部利用できない機能があります
Attenuation correction of myocardial SPECT by scatter-photopeak window method in normal subjects
- フォーマット:
- 論文
- 責任表示:
- Okuda, Koichi ; Nakajima, Kenichi ; Motomura, Nobutoku ; Kubota, Masahiro ; Yamaki, Noriyasu ; Maeda, Hisato ; Matsuo, Shinro ; Kinuya, Seigo
- 言語:
- 英語
- 出版情報:
- 2009-07-01
- 著者名:
Okuda, Koichi Nakajima, Kenichi Motomura, Nobutoku Kubota, Masahiro Yamaki, Noriyasu Maeda, Hisato Matsuo, Shinro Kinuya, Seigo - 掲載情報:
- Annals of Nuclear Medicine
- ISSN:
- 0914-7187
- 巻:
- 23
- 通号:
- 5
- 開始ページ:
- 501
- 終了ページ:
- 506
- バージョン:
- author
- 概要:
- 金沢大学医薬保健研究域<br />Objective: Segmentation with scatter and photopeak window data using attenuation correction (SSPAC) method can provide a patient-specific non-uniform attenuation coefficient map only by using photopeak and scatter ima … ges without X-ray computed tomography (CT). The purpose of this study is to evaluate the performance of attenuation correction (AC) by the SSPAC method on normal myocardial perfusion database. Methods: A total of 32 sets of exercise-rest myocardial images with Tc-99 m-sestamibi were acquired in both photopeak (140 keV ± 10%) and scatter (7% of lower side of the photopeak window) energy windows. Myocardial perfusion databases by the SSPAC method and non-AC (NC) were created from 15 female and 17 male subjects with low likelihood of cardiac disease using quantitative perfusion SPECT software. Segmental myocardial counts of a 17-segment model from these databases were compared on the basis of paired t test. Results: AC average myocardial perfusion count was significantly higher than that in NC in the septal and inferior regions (P < 0.02). On the contrary, AC average count was significantly lower in the anterolateral and apical regions (P < 0.01). Coefficient variation of the AC count in the mid, apical and apex regions was lower than that of NC. Conclusions: The SSPAC method can improve average myocardial perfusion uptake in the septal and inferior regions and provide uniform distribution of myocardial perfusion. The SSPAC method could be a practical method of attenuation correction without X-ray CT. © 2009 The Japanese Society of Nuclear Medicine. 続きを見る
- URL:
- http://hdl.handle.net/2297/18232
類似資料:
Japanese Society of Nuclear Medicine 日本核医学会 / Springer Verlag (Germany) | |
Springer Berlin (open access journals) |
Springer verlag (Germany) / The Japanese Society of Nuclear Medicine |
The Japanese Society of Nuclear Medicine = 日本核医学会 / Springer-Verlag Tokyo | |
THE JAPANESE CIRCULATION SOCIETY 日本循環器学会 |
日本核医学会 = Japanese Society of Nuclear Medicine |
Springer Japan / 日本核医学会 = the Japanese Society of Nuclear Medicine |
Springer Verlag (Germany) / 日本核医学会 = the Japanese Society of Nuclear Medicine |
Lippincott, Williams & Wilkins |