※一部利用できない機能があります
光電容積脈波式血中アルコール濃度計測装置の開発: in vivo試験による予備的検討
- フォーマット:
- 論文
- 責任表示:
- 山越, 健弘 ; 小川, 充洋 ; 松村, 健太 ; 板坂, 優希 ; 宮崎, 慎平 ; 山越, 康弘 ; Rolfe, Peter ; 廣瀬, 元 ; 山越, 憲一
- 言語:
- 日本語
- 出版情報:
- Japanese Society for Medical and Biological Engineering = 日本生体医工学会 JSMBE, 2012-01-01
- 著者名:
山越, 健弘 小川, 充洋 松村, 健太 板坂, 優希 宮崎, 慎平 山越, 康弘 Rolfe, Peter 廣瀬, 元 山越, 憲一 - 掲載情報:
- Transactions of Japanese Society for Medical and Biological Engineering
- ISSN:
- 1347-443x
- 巻:
- 50
- 通号:
- 2
- 開始ページ:
- 237
- 終了ページ:
- 247
- バージョン:
- publisher
- 概要:
- In this preliminary study, we examined in human volunteers the performance of the developed prototype device for non-invasive quantification of blood alcohol concentration (BAC) by near-infrared light which is highly transparent to the body. We aimed at applying the results to the final goal of developing a novel alcohol-based vehicle ignition-interlock device. Accumulating evidence shows that one of the ethyl alcohol absorption peaks in the near-infrared region is … present at 1,185 nm. We combined this with our recent development of a non-invasive optical method for blood glucose measurement, which we call pulse glucometry, using blood volume pulsations in a finger within a cardiac cycle. Thus, we developed a novel method, pulse alcometry, for non-invasive measurement of BAC. We calculated second derivative values of optical density (OD λ") to remove baseline over a band including three wavelengths, 1,150 nm, 1,185 nm, and 1,220 nm. Then, a simple linear regression analysis was performed with the measured OD λ" to predict BAC levels. In 3 healthy male volunteers, during alcohol intake and washout, periodic optical measurements using the present device were made simultaneously with collection of blood samples for in vitro BAC analysis. In leave-one-out cross validations within an individual, the measured BAC and the predicted BAC correlated well (r = 0.773~0.846, mean absolute error = 0.134~0.333mg/ml). We conclude that, from the results of this preliminary study, the new method appears to be able to estimate BAC levels non-invasively. However, further investigations in a larger group of subjects will be needed in order to determine fully the operational performance of this new measurement system. 続きを見る
- URL:
- http://hdl.handle.net/2297/32473
類似資料:
生体医工学会 |
Japanese Society for Medical and Biological Engineering = 生体医工学 : 日本エム・イー学会 |
日本生体医工学会 = Japanese Society for Medical and Biological Engineering |
Japanese Society for Medical and Biological Engineering = 日本生体医工学会 JSMBE |
日本生体医工学会 = the Japanese Society for Medical and Biological Engineering |
日本生体医工学会 JSMBE = Japan Society for Medical and Biological Engineering |
日本生体医工学会 = Japanese Society for medical and Bilogical Engineering | |
日本生体医工学会 = Japanese Society for medical and Bilogical Engineering |
日本生体医工学会 |
日本生体医工学会 |
The Japanese Society for Cognitive Psychology = 日本認知心理学会 |