131I治療患者周辺空間線量率分布の解析
- フォーマット:
- 論文
- 責任表示:
- 折戸, 武郎 ; 古賀, 佑彦 ; 竹内, 昭 ; 越田, 吉郎 ; 前川, 龍一
- 言語:
- 日本語
- 出版情報:
- 日本保健物理学会 = Japan Health Physics Society, 1984-01-01
- 著者名:
- 掲載情報:
- 保健物理 = Japanese Journal of Health Physics
- ISSN:
- 0367-6110
- 巻:
- 19
- 通号:
- 1
- 開始ページ:
- 3
- 終了ページ:
- 11
- バージョン:
- publisher
- 概要:
- Spatial dose distribution curves based on the measurement of clinical cases, theoretical and experimental analyses were studied around the patients treated with 131I for thyroid carcinoma. When the maximum activity in a patient was 15mCi, external exposure at 50cm from a side of the subject's was 7.64mR/hr for theoretical value, 6.5mR/hr for experimental value, and 3.2mR/hr for clinical case. The total exposure at 1m from the side of the breast in clinical … cases 1, 2 and 3 were obtained 0.775, 0.197 and 0.079R, respectively. The result of case 1 suggested that special restriction need be placed on the patient's proximity to other individual. 続きを見る