※一部利用できない機能があります
Technetium-99m-Tetrofosmin Uptakes on Dipyridamole-Stress Planar Imaging Comparison with Those in Excised Rat Organs
- フォーマット:
- 論文
- 責任表示:
- Onoguchi, Masahisa ; Takayama, Teruhiko ; Tonami, Norihisa ; Mizukami, Yuji ; Kyogoku, Shinsuke ; Naoi, Yutaka ; Irimoto, Masahiro ; Maehara, Tadayuki
- 言語:
- 英語
- 出版情報:
- 金沢大学医学部保健学科, 2000-12-01
- 著者名:
Onoguchi, Masahisa Takayama, Teruhiko Tonami, Norihisa Mizukami, Yuji Kyogoku, Shinsuke Naoi, Yutaka Irimoto, Masahiro Maehara, Tadayuki - 掲載情報:
- 金沢大学医学部保健学科紀要
- ISSN:
- 1342-7318
- 巻:
- 24
- 通号:
- 1
- 開始ページ:
- 21
- 終了ページ:
- 29
- バージョン:
- publisher
- 概要:
- We studied how precisely images reflect tracer uptake .in the myocardium, and examined what degree technetium-99m-tetrofosmin (c-tetrofosmin) in the liver and gastrointestine gave the effect to a myocardial image. After administering dipyridamole and 99m Tc tetrofosmin to normal rats, we compared the myocardial uptakes obtained using a gamma camera with the actual uptakes in the excised organs. Methods : Thirty-seven rats were used. Following imaging the … anterior view at 5, 10, 15, 30, 60 and 90 min after admini stration of the tracer, uptakes in the heart, lung, liver and blood were estimated with a well-type scintillation counter (WC) and represented as percentage of the injected dose per gram of tissue (%ID/g). The regions of interest (ROis) were placed on planar images (PI) and the uptake in each organ was estimated as percentage of the injected dose per pixel (%ID/pixel). The ratios of PI-to-WC and heart-to-organ were also evaluated. Results : Cardiac uptake with WC was 1.688%± 0.395% at 10 min post-injection. On the other hand, that with PI was 1.855%±0.965% at 10 min post-injection. There were particularly great differences from 15 min post-injection between both measurements (PI/WC ratio : about 1.2 times). Pulmonary uptake with WC was the maximum at 15 min (0.861%± 0.387%) post-injection, and there was. hardly a variation in the activity later than 15 min. However, PI measurement showed the maximum value at 15 min (0.777%±0.163%), and decreased gradually. Hepatic uptake with WC was the maximum at 5 min (1.545%±0.563 %), and rapidly decreased. On the other hand, PI measurement showed higher value than WC as" the whole. Conclusion : Pl measurement showed higher uptakes in each organ than WC measurement. There were great differences between both measurements, at late phase particularly. As one of these causes, it was considered that the decrease of activity in blood was different from that in each organ with increasing time. 続きを見る
- URL:
- http://hdl.handle.net/2297/45917
類似資料:
Society of Nuclear Medicine |
Society of Nuclear Medicine |
THE SOCIETY OF NUCLEAR MEDICINE INC |
金沢大学医学部保健学科 = School of Health Sciences,Faculty of Medicine, Kanazawa University |
金沢大学医薬保健研究域保健学系 | |
Society of Nuclear Medicine |
Society of Nuclear Medicine |