1.

論文

論文
Yachi, Kaoru ; Nemoto, Tetsu ; Ogai, Kazuhiro ; Kobayashi, Toshio ; Shimada, Keiko ; 谷内, 薫 ; 根本, 鉄 ; 大貝, 和裕 ; 小林, 登史夫 ; 島田, 啓子
出版情報: Journal of wellness and health care = Journal of wellness and health care.  42  pp.41-50,  2018-08-01.  Wellness and Health Care Society — ウェルネス・ヘルスケア学会
URL: http://hdl.handle.net/2297/00051943
概要: Proper management of overall health is critical to provide care for low-birth-weight infants (LBWIs). Clinically, the ex tent of body movement (BM) is a major indicator of the overall health of LBWIs. The present study was performed to determine the amount of BM that is effective for health management by comparing the quantitative results of amount of BM and weight gain. A bed sensor utilizing a dual piezoelectric element was used for BM measurement. BM was measured throughout the day, and the average amount of BM in a 5-minute period was calculated. In addition, BM data of 33 study subjects were further analyzed to determine the level of BM, i.e., categorized as BM-0 to BM-20, associated with significant weight gain, which was also identified as the coefficients of CA to CE according to the linear and quadratic approximation equations. Statistical analyses between BM-0 to BM-20 and CA to CE were performed by data-mining analysis and multiple linear regression analysis to examine the relations among observed variables and coefficients. The results showed that the amount of BM increased with increasing weight gain of the subjects. Gradual trends were observed between BM-0 to BM-20 and CA to CE, which could be used for routine automatic monitoring of LEWIs.<br />低出生体重児のケアを提供する上で、全身状態の適切な管理が重要である。臨床において、体動は低出生体重児の全身管理の指標の一つである。本研究では、低出生体重児の体動を定量化し、体重増加との関係を比較することにより、全身管理の指標となる体動量を明らかにすることを目的とした。体動計測装置は、デュアル圧電素子を用いたベッドセンサを用いた。33 名の低出生体重児を調査対象とし、体動を 24 時間測定し、 5 分間の平均体動量を算出した。統計解析にはデータマイニング解析および多変量解析を用いて統計学的分析を行った。調査の結果により、低出生体重児の体重を区分してみた結果、体重が大きい児の方が体動が大きいことが示された。また、BM- 0 〜 BM-20 と CA 〜 CE の間には一定の傾向が認められ、体動計測装置は低出生体重児の体動を自動的にモニタリングできるルーチンの手法として用いることができる。 続きを見る
2.

論文

論文
谷内, 薫 ; 根本, 鉄 ; 島田, 啓子
出版情報: 金沢大学つるま保健学会誌 = Journal of the Tsuruma Health Science Society, Kanazawa University.  40  pp.11-19,  2016-07-29.  金沢大学つるま保健学会 = Tsuruma Health Science Society, Kanazawa University
URL: http://hdl.handle.net/2297/45869
概要: 目的:本研究の目的は、低出生体重児の体動を定量化し体重との関係を明らかにすることである。 対象および方法:35 名の低出生体重児を対象に圧電素子を用いた体動計を保育器内のマット下に設置し、24 時間の連続測定を 4 ないし 7 日間体動計測 を行った。体動の分析は、調査時体重を 900 - 1399g、1400 - 1699g、1700 - 1999g、2000 - 2399g の 4 群に分類し、それぞれの 1 日あたりの体動の平均値を算出した。調査時体重と 1 日の体動数の相関関係と回帰分析を行った。 結果:1 日あたりの体動数の平均値(± SD)は、調査時体重 900 - 1399g(n=6)では525 ± 326 回、1400 - 1699g(n=12)では 772 ± 203 回、1700 - 1999g(n=12)では 1002± 303 回、2000 - 2399g(n=5)では 1096 ± 180 回であり、調査時体重が大きいほど体動数が増加する傾向を示した。調査時体重の平均値(± SD)は 1693.8 ± 308.9g、24 時間体動数の平均値(± SD)は 854.4 ± 316.6 であり、両者は r=0.588 で強い正の相関を認めた。調査時体重と体動数の回帰分析より y = 0.6031x - 167.12 で求められ、対象全員が 95% 信頼誤差内にあった。 結論:圧電素子を 2 個用いた高感度の体振動計を用いることで、非侵襲的に低出生体重児の体動の検出ができ、調査時体重と 1 日の体動数には強い正の相関を認めた。 続きを見る
3.

論文

論文
田淵, 紀子 ; 根本, 鉄 ; 島田, 啓子 ; 松田, 康子 ; 間島, 佳代乃 ; 古田, ひろみ
出版情報: 金沢大学つるま保健学会誌 = Journal of the Tsuruma Health Science Society Kanazawa University.  35  pp.71-78,  2011-12-27.  金沢大学つるま保健学会 = the Tsuruma Health Science Society, Kanazawa University
URL: http://hdl.handle.net/2297/29773
概要: 【目的】本研究目的は、保温に効果があるとされる“テビロン”肌着を新生児に着用させ、発汗データロガーを用いて、肌着の内側と外側の温湿度測定により臨床での有用性を検討することである。 【方法】対象は、2010年9月~2011年6月にA病院で正期 産、経膣分娩にて出生した新生児8例である。データ収集方法は、出生後テビロン肌着を着衣し、翌日の脱衣までの間の肌着内外の温度と相対湿度を身体発汗データロガーにて連続測定した。その間の新生児の行動(啼泣、授乳等)は授乳記録用紙から把握した。10秒ごとに記録された温度と相対湿度データは解析ソフトOrigin 8を用いて絶対湿度に変換した後、発汗のタイミングと発汗 レベルを検出した。発汗のタイミングと発汗レベルは経時的に新生児の啼泣・授乳等の行動記録を合わせて分析した。 【結果】衣服内の温度は32℃ から38℃ の範囲であった。相対湿度は20%から90%前後であった。啼泣時は、内側絶対湿度が急激に上昇後下降した。抱っこや授乳時は外側の絶対湿度が急上昇後下降するなど絶対湿度の変動が大きかった。一方、睡眠時は皮膚蒸散量が減少しており、内側の温湿度が外側の温湿度より高かった。また、母親が抱っこや授乳・添え乳時に肌着の外側の温度が高くなる傾向があった。 【考察】今回の結果より、テビロン肌着は水分を外に吐き出す機能を有しており、新生児が啼泣するなど発汗しても、すみやかにさらっとした爽快感が得られると考えられた。また、新生児と母親の行動(睡眠、啼泣、授乳、添え乳、添い寝)等の記録と肌着内外の温湿度データが示す解釈とが一致していたことから、連続モニターが示す発汗データロガーは、新生児の状態と母親の育児行動を推察し得る有益なデータにもなり得ることが考えられ、さらに母子関係を予測する指標としての可能性が示唆された。 【結論】テビロン肌着は、水分量を外に吐き出す機能を有しており、臨床での有用性が示唆された。[Objectives] The purpose of this study was to test the effectiveness of underwear made of “Teviron” material, with reportedly excellent thermal insulation and moisture vapor transmission, for newborn use. A sweat data logger was put inside and outside the underwear worn by newborns and the clinical usefulness was evaluated by examining the environment inside and outside the underwear. [Methods] The study involved 8 newborns vaginally delivered at full-term in Hospital A, between September 2010 and June 2011. Regarding the data collection method, Teviron underwear was put on newborns after birth, and serial measurements of temperature inside and outside the underwear, and relative humidity using a body sweat data logger were taken until the underwear were removed the next day. Newborns’ behaviors during the time (e.g., crying and breast-milk intake) were recorded on report forms. Data on temperature and relative humidity recorded every 10 seconds were converted to absolute humidity using the analysis software, Origin 8. The timing and level of sweating were also investigated, and analyzed over time based on behavioral records such as newborns’ crying and breast-milk intake. [Results] Temperature inside the clothing ranged from 32 to 38℃. The relative humidity ranged from 20 to approximately 90%. When crying, the absolute humidity in the clothing increased and then decreased rapidly. When the newborns were being held and nursed, the absolute humidity outside the clothing increased and then decreased rapidly, indicating that the absolute humidity ranged markedly. Meanwhile, when sleeping, the inside temperature and humidity were higher than the outside values, because evaporative losses from the skin decreased. When mothers breast fed newborns while holding them in a transverse lying position, the temperature outside the underwear tended to increase. [Discussion] These results suggest the Teviron underwear has the function of letting moisture out ; thus newborns can rapidly feel dry to the touch even though they become sweaty due to crying. Because behavioral records of newborns and mothers - e.g., sleeping, crying, lactating, and sleeping together - agreed with the interpretation based on temperature and humidity data inside and outside the underwear, the sweating data logger, employing serial monitoring may provide useful data whereby we can infer newborns’ activity and mothers’ child-care behavior, and there is a possibility of it becoming an indicator whereby we can predict maternal and child relationships. [Conclusion] Teviron underwear had the function of letting moisture out, possibly contributing to the comfort of newborns. 続きを見る
4.

論文

論文
北村, 敬一郎 ; 根本, 鉄 ; 高田, 重夫
出版情報: 金沢大学つるま保健学会誌.  27  pp.47-54,  2003-12-01. 
URL: http://hdl.handle.net/2297/6120
概要: 金沢大学 医学部保健学科 生体情報学<br />原著論文/比較研究
5.

論文

論文
栗田, 俊治 ; 根本, 鉄 ; 北村, 敬一郎
出版情報: 生体医工学 : 日本エム・イー学会誌.  44  pp.327-327,  2006-06-10.  日本生体医工学会
URL: http://hdl.handle.net/2297/3655
概要: 金沢大学大学院医学系研究科先端医療技術学
6.

論文

論文
谷内, 薫 ; 根本, 鉄 ; 島田, 啓子
出版情報: 日本助産学会誌 = Journal of Japan Academy of Midwifery.  29  pp.15-21,  2015-01-01.  日本助産学会 = Japan Academy of Midwifery
URL: http://hdl.handle.net/2297/44877
概要: 目 的  出生後早期における児の中枢および末梢深部温と腋窩温を同時測定することにより,Late Preterm児の至適温度環境を探る。また,現状の腋窩温による体温管理のあり方について検討する。 対象と方法  対象はLate Preterm児 6名であり,生後4~12時間の中枢深部温,末梢深部温および腋窩温を同時測定した。中枢深部温と末梢深部温は深部体温計を使用し,体温プローベは腹壁(中枢深部温)と足底(末梢深部温)に装着し,1分毎に連続測定を行った。腋窩温は2~3時間毎に測定し,体温データは平均と標準偏差を求めた。また,腋窩温と中枢深部温は測定回数が異なるため,中枢深部温は比較する腋窩温を測定した時間を含む前後15分の平均値をとり,腋窩温との相関および温度差を求めた。同時に各ケースの体温変化のパターンも視覚的に分析した。 結 果  腋窩温は平均36.6~36.9℃(平均36.8℃)であり,Late Preterm児のガイドラインにある腋窩温で管理されていた。中枢深部温は36.9~37.2℃(平均37.1℃)であり,中枢深部温は腋窩温より0.3℃高い値で強い正相関を認めていた(r=0.75~0.99)。また,中枢深部温は変動幅が小さく,ほぼ一定の値を示していたが,末梢深部温の変動幅は大きく,ケースによりさまざまな変動パターンを示していた。 結 論 1.腋窩温は中枢深部温よりも約0.3℃低く,強い正の相関を認めたが,腋窩温と末梢深部温は有意な相関関係を認めなかった。 2.腋窩温がガイドラインの範囲で管理されていても,中枢深部温と末梢深部温の差は0.47~1.87℃(平均1.00℃)であり,各ケースにより,その差はさまざまな推移を示していた。 3.Late Preterm児において中枢と末梢温の同時測定は出生後早期より行うことの有効性が示唆された。 Objective To examine optimal temperature environments for late preterm infants during the early postnatal period by simultaneously measuring the central and peripheral deep body and axillary temperatures, while discussing the current status of temperature control based on the axillary temperature. Subjects and Methods The central and peripheral deep body and axillary temperatures of 6 late preterm infants were simultaneously measured 4 to 12 hours after birth. The central and peripheral deep body temperatures were continuously measured at intervals of 1 minute using a deep body thermometer and attaching a temperature probe to the abdominal wall (central) and plantar (peripheral). The axillary temperature was measured at intervals of 2 to 3 hours. Subsequently, the means and standard deviations of the obtained temperature data were calculated, while visually analyzing the temperature fluctuation pattern in each infant. Results The axillary temperature ranged from 36.6 to 36.9 (mean: 36.8) degrees C; these values were within the range determined in the Guidelines for Late Preterm Infant Management. The central deep body temperature ranged from 36.9 to 37.2 (37.1) degrees C, showing a strong positive correlation at a temperature 0.3 degrees C higher compared to that of the axillary temperature (r=0.75 to 0.99). Furthermore, while the central deep body temperature was generally constant, showing a narrow range of fluctuation, the peripheral deep body temperature showed a wide range of fluctuation, and its pattern varied among infants. The infant in whom the difference between the central and peripheral deep body temperatures was the greatest had experienced mild birth asphyxia. Conclusion 1. The axillary temperature showed a strong positive correlation at a temperature approximately 0.3 degrees C lower than that of the central deep body temperature. 2. It may be difficult to create optimal temperature environments for late preterm infants based on the axillary temperature only. 3. It may be effective to simultaneously measure the central and peripheral deep body temperatures during the early postnatal period in late preterm infants. 続きを見る
7.

論文

論文
北村, 敬一郎 ; 中野, 淳 ; 川部, 季美 ; 早川, 和一 ; 佐藤, 雄亮 ; 根本, 鉄 ; 大嶋, 雄治 ; 島崎, 洋平 ; 遠藤, 雅人 ; 服部, 淳彦 ; 鈴木, 信雄
出版情報: 日本海域研究 = Annals of th e Research Institute of the Japan Sea Region.  42  pp.27-34,  2011-03-10.  金沢大学環日本海域環境研究センター = Kanazawa University Institute of Nature and Environmental Technology
URL: http://hdl.handle.net/2297/30435
8.

論文

論文
鈴木, 信雄 ; 北村, 敬一郎 ; 根本, 鉄 ; 服部, 淳彦
出版情報: 年報 金沢大学環日本海域環境研究センター = K-INET Kanazawa University.  2007  pp.109-110,  2008-07-31.  金沢大学環日本海域環境研究センター = Institute of Nature and Environmental Technology, Kanazawa University, Japan
URL: http://hdl.handle.net/2297/16993
9.

論文

論文
鈴木, 信雄 ; 北村, 敬一郎 ; 根本, 鉄 ; 服部, 淳彦
出版情報: 金沢大学環日本海域環境研究センター臨海実験施設研究概要・年次報告= Annual Report of Noto Marine Laboratory Institute of Nature and Environmental Technology, Kanazawa University.  6  pp.14-15,  2008-01-01.  金沢大学環日本海域環境研究センター臨海実験施設
URL: http://hdl.handle.net/2297/42959
10.

論文

論文
根本, 鉄 ; Nemoto, Tetsu
出版情報: 平成23(2011)年度 科学研究費補助金 基盤研究(C) 研究成果報告書 = 2011 Fiscal Year Final Research Report.  2009 – 2011  pp.5p.-,  2012-05-10. 
URL: http://hdl.handle.net/2297/00059426
概要: 金沢大学医薬保健研究域保健学系<br />プローブの体表面と金属外気面の温度差と熱抵抗比から皮下深部温を測定する非加熱型深部体温度計を開発した。非加熱型深部体温計は厚さの異なる断熱材で皮膚表面を覆った時、断熱材の熱抵抗比kを一定とし皮下組織 の熱抵抗値が消去できる方法である。熱流補償法の深部体温計と非加熱加熱深部温の比較において、学生20人の側頭部深部温は36. 85±0. 25℃、熱補償法では36. 87℃±0. 26℃と良く一致し、2つの方法には有意の正の相関(p<0. 01)が得られた。<br />The deep body thermometer of the non-heating type when covered the skin surface with a different insulation material of the thickness was developed to measure subcutaneous deep body temperature. The subcutaneous thermal resistance can be neglected from the difference of temperature of a skin body surface and the metal upper side and the thermal resistance ratio of the insulation material. The average of subcutaneous deep body temperature measurements taken using both the non-heating type and then the zero-heat-flow thermometers from the foreheads of 17 healthy subjects were 37. 08℃and 37. 02℃, respectively. In addition, the correlation coefficient between the values obtained by the 2 methods was 0. 970(p<0. 001). These results showed that the non-heating type thermometer can be used for monitoring the deep body temperature as accurately as the conventional method.<br />研究課題/領域番号:21500405, 研究期間(年度):2009 – 2011 続きを見る